Victron Energy MultiPlus 48/3000/35-50 VE.Bus – PMP483021010

Description

 

The MultiPlus, as the name suggests, is a combined inverter and charger in one elegant package. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, plus multiple system integration features.

 

Features

Two AC Outputs

The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater for example can be connected to this output (second output available on models rated at 3 kVA and more).

Virtually unlimited power thanks to parallel operation

Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will provide 25 kW / 30 kVA output power with 720 Amps charging capacity. Three phase capability In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more than 2000 Amps charging capacity.

PowerControl – Dealing with limited generator, shore side or grid power

The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

PowerAssist – Boosting the capacity of shore or generator power

This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

Solar energy: AC power available even during a grid failure

The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems. Loss of mains detection software is available.

System configuring

  • In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure.
  • Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System Configurator software.
      Brand

      Victron Energy

      Manufacturer Part Number

      PMP483021010

      Voltage

      48

      Transfer Switch (A)

      16 or 50

      Cont. Output Power at 25°C (VA)

      3000

      Peak Power (W)

      6000

      Max Efficiency

      95%

      Zero Load Power (W)

      25

      Charge Current House Battery (A)

      35

      Charge Current Starter Battery (A)

      4 (12 V and 24 V models only

      Battery Temperature Sensor

      Yes

      Programmable Relay

      Yes

      Remote on-off

      Yes

      Protection Category

      IP21

      Dimensions

      H362 x W258 x D218mm

      Weight (kg)

      18

      Warranty

      5 Years

      Country of Manufacture

      India


      Product form

      CLICK HERE FOR SPEC SHEETS   The MultiPlus, as the name suggests, is a combined inverter and charger in one... Read more

      £608.00 Exc. VAT
      £729.60 Inc. VAT

      • Quality
      • Reliabilty
      • Trusted

      Description

       

      The MultiPlus, as the name suggests, is a combined inverter and charger in one elegant package. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, plus multiple system integration features.

       

      Features

      Two AC Outputs

      The main output has no break functionality. The MultiPlus takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater for example can be connected to this output (second output available on models rated at 3 kVA and more).

      Virtually unlimited power thanks to parallel operation

      Up to 6 Multis can operate in parallel to achieve higher power output. Six 24/5000/120 units, for example, will provide 25 kW / 30 kVA output power with 720 Amps charging capacity. Three phase capability In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel connected for a huge 75 kW / 90 kVA inverter and more than 2000 Amps charging capacity.

      PowerControl – Dealing with limited generator, shore side or grid power

      The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side supply (nearly 10 A per 5 kVA Multi at 230 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

      PowerAssist – Boosting the capacity of shore or generator power

      This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

      Solar energy: AC power available even during a grid failure

      The MultiPlus can be used in off grid as well as grid connected PV and other alternative energy systems. Loss of mains detection software is available.

      System configuring

      • In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure.
      • Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System Configurator software.
          Brand

          Victron Energy

          Manufacturer Part Number

          PMP483021010

          Voltage

          48

          Transfer Switch (A)

          16 or 50

          Cont. Output Power at 25°C (VA)

          3000

          Peak Power (W)

          6000

          Max Efficiency

          95%

          Zero Load Power (W)

          25

          Charge Current House Battery (A)

          35

          Charge Current Starter Battery (A)

          4 (12 V and 24 V models only

          Battery Temperature Sensor

          Yes

          Programmable Relay

          Yes

          Remote on-off

          Yes

          Protection Category

          IP21

          Dimensions

          H362 x W258 x D218mm

          Weight (kg)

          18

          Warranty

          5 Years

          Country of Manufacture

          India


          Forgot Password


          Back to top